Описания процессов
- Overview
- Live steam temperature measurement
- Reheat steam flow measurement
- Pressure measurement of HP steam
- Pressure measurement of reheat steam
- Process pressure measurement after steam bypass
- Process pressure measurement after steam bypass
- Live steam temperature measurement
- Live steam pressure measurement
- Temperature measurement lubrication system
- Reheat steam flow measurement
- Turbine pressure measurement
- Level measurement of condenser
- Temperature measurement bypass steam
- Temperature measurement lubrication system
- Temperature measurement lubrication system
- Pressure measurement lubrication system
- Strainer resistance measurement
- Temperature measurement of lube oil
- Level measurement of lube oil
- Level measurement of lube oil system
Steam Turbine Generator (STG) in combined cycle power plant
Safe and reliable ST operation
In general, the design of a steam turbine is classified by the condition of the turbine exhaust i.e. backpressure, condensing, extraction and reheat. Steam turbines in combined cycle applications are specifically developed as multi-pressure condensing types, using water cooling provided from a cooling tower or air cooler, and direct coupled to a generator and optimized for reheat. A steam turbine generator is defined by the various system components, such as: HP-IP-LP turbine, generator, lubrication and hydraulic oil system, gland steam supply, vacuum breaking and drain systems, and turbine measurement, protection and control system.
High-Pressure Steam BypassIn a triple pressure with reheat HRSG, the high-pressure steam bypass is located downstream of the HP superheater. During plant start-up the high-pressure steam bypass will release the HP steam to the cold reheat system according to the requirements of the steam turbine. If, in this system, the pressure of the HP steam exceeds the setpoint of the steam bypass controller, the HP steam bypass opens and releases the HP steam to the cold reheat system. Then, via the reheater section through the intermediate-pressure bypass station to the steam is released to the steam turbine condenser. Many of these industrial boiler co-generation applications are also able to run in Island Operation in case of a national power grid failure, to provide the required process steam to the adjacent production plant, and facilitate a safe shut down.
Pressure and temperature measurements are pivotal for a safe and efficient turbine operation. KROHNE offers a full range of state of the art OPTIBAR absolute-, gauge- and differential-pressure transmitters. The OPTITEMP temperature measurement series offers a complete capability, including thermowells, sensors and transmitters suited for power generation applications, all supplied with static and dynamic stress calculations and the required documentation.
Требования к данной позиции измерения
- dynamic calculations
- fast response
- vibration resistant
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control and performance testing
- ASME PTC, IEC 60953
- redundancy, e.g. materials P91/P92
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- High pressure
- High temperature
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- High pressure
- High temperature
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- High pressure
- High temperature
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- High pressure
- High temperature
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- dynamic calculations
- fast response
- vibration resistant
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- High pressure
- Low maintanance requirements
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control and performance testing
- ASME PTC, IEC 60953
- redundancy, e.g. materials P91/P92
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Redundancy
- fast response
- Overload protection
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Redundancy
- Low pressure
- Diaphram seals
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- dynamic calculations
- fast response
- vibration resistant
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control
Рекомендуемые изделия и системы
Требования к данной позиции измерения
- Process control